802.589.0911 Live Chat With Us

Finish Selecting Your Vehicle

Choose your Submodel for your 2013 Kia Optima

  • Hybrid

Shop By Brand

The Following brands are available based on your search.

  • Bosch
    Bosch
  • Denso
    Denso
  • Mando
    Mando
  • NGK
    NGK
  • Spectra
    Spectra
  • Walker
    Walker

Showing Products For 2013 Kia Optima Oxygen Sensor

Below are all the different brands and applications for 2013 Kia Optima Oxygen Sensor

Showing 21 - 30 of 49 Products for Oxygen Sensor.

Refine Your Search

Walker
2013 Kia Optima Oxygen Sensor - Upstream 4 Cyl 2.4L Walker - Walker OE

P311-44A4579    250-25062  New

Qty:
108.13
Walker Oxygen Sensor  Upstream
  • Walker Products 250-25062 Oxygen Sensor 5-W Wideband
  • ; Upstream Calif-ESV
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 19.8
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 5
    • Wiring Harness Length: 16.26
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Upstream
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Naturally Aspirated GAS 7 FI Upstream L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Downstream 4 Cyl 2.4L Walker - Walker OE

P311-0E606AE    250-24913  New

Qty:
65.35
Walker Oxygen Sensor  Downstream
  • Walker Products 250-24913 Oxygen Sensor 4-W Direct Fit
  • ; Downstream Non Calif-ESV
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Gender: Female
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 21.77
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 4
    • Wiring Harness Length: 18.23
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Downstream
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Naturally Aspirated GAS 7 FI Downstream L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Upstream 4 Cyl 2.0L Walker - Walker OE

P311-44A4579    250-25062  New

Qty:
108.13
Walker Oxygen Sensor  Upstream
  • Walker Products 250-25062 Oxygen Sensor 5-W Wideband
  • ; Upstream
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 19.8
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 5
    • Wiring Harness Length: 16.26
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Upstream
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Turbocharged GAS 6 FI Upstream L 4 Cyl 2.0L 122 1998
Walker
2013 Kia Optima Oxygen Sensor - Center 4 Cyl 2.4L Walker - Walker OE

P311-3E6EADE    250-24878  New

Qty:
55.25
Walker Oxygen Sensor  Center
  • Walker Products 250-24878 Oxygen Sensor 4-W Direct Fit
  • ; Center Calif-ESV
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 24.72
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 4
    • Wiring Harness Length: 21.18
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Center
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Naturally Aspirated GAS 7 FI Center L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Downstream 4 Cyl 2.4L Walker - Walker Aftermarket

P311-339B9C0    350-34628  New

Qty:
58.48
Walker Oxygen Sensor  Downstream
  • Walker Products 350-34628 Oxygen Sensor 4-W Direct Fit
  • ; Non Calif-ESV Downstream
  • Walker Aftermarket
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Gender: Female
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 21.77
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 4
    • Wiring Harness Length: 18.23
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Downstream
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Naturally Aspirated GAS 7 FI Downstream L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Upstream 4 Cyl 2.4L Walker - Walker OE

P311-44A4579    250-25062  New

Qty:
108.13
Walker Oxygen Sensor  Upstream
  • Walker Products 250-25062 Oxygen Sensor 5-W Wideband
  • ; Calif-ESV B1S1
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 19.8
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 5
    • Wiring Harness Length: 16.26
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Upstream
Additional Fitment Information:
Vehicle Transmission Aspiration Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Automatic Naturally Aspirated 7 FI Upstream L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Downstream 4 Cyl 2.4L Walker - Walker OE

P311-3E6EADE    250-24878  New

Qty:
55.25
Walker Oxygen Sensor  Downstream
  • Walker Products 250-24878 Oxygen Sensor 4-W Direct Fit
  • ; B1S2
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 24.72
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 4
    • Wiring Harness Length: 21.18
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Downstream
Additional Fitment Information:
Vehicle Submodel Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Hybrid Naturally Aspirated ELECTRIC/GAS D FI Downstream L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Downstream 4 Cyl 2.4L Walker - Walker OE

P311-0E606AE    250-24913  New

Qty:
65.35
Walker Oxygen Sensor  Downstream
  • Walker Products 250-24913 Oxygen Sensor 4-W Direct Fit
  • ; Non Calif-ESV B1S2
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Gender: Female
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 21.77
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 4
    • Wiring Harness Length: 18.23
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Downstream
Additional Fitment Information:
Vehicle Transmission Aspiration Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Automatic Naturally Aspirated 7 FI Downstream L 4 Cyl 2.4L - 2359
Walker
2013 Kia Optima Oxygen Sensor - Upstream 4 Cyl 2.0L Walker - Walker OE

P311-44A4579    250-25062  New

Qty:
108.13
Walker Oxygen Sensor  Upstream
  • Walker Products 250-25062 Oxygen Sensor 5-W Wideband
  • ; B1S1
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 19.8
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 5
    • Wiring Harness Length: 16.26
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Upstream
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Turbocharged GAS 6 FI Upstream L 4 Cyl 2.0L 122 1998
Walker
2013 Kia Optima Oxygen Sensor - Downstream 4 Cyl 2.0L Walker - Walker OE

P311-0E606AE    250-24913  New

Qty:
65.35
Walker Oxygen Sensor  Downstream
  • Walker Products 250-24913 Oxygen Sensor 4-W Direct Fit
  • ; B1S2
  • Walker OE
  • Product Attributes:
    • CA_Prop65_Nickel: Warning: This Product Can Expose You To Chemicals, Including Nickel And Nickel Alloyed Stainless Steel, Which Are Known To The State Of California To Cause Cancer Or Birth Defects Or Other Reproductive Harm. Www.p65warnings.ca.gov
    • Connector Gender: Female
    • Connector Shape: Radiused Polygon
    • Mounting Type: Threaded
    • Overall Length: 21.77
    • Sensor Type: Heated
    • Thread Diameter: 18.0
    • Wire Gauge Measurement: 20
    • Wire Quantity: 4
    • Wiring Harness Length: 18.23
  • Walker Products Engine Management and Oxygen/Air-Fuel sensors have been engineered and developed to be an Original Equipment Manufacturers replacement for many vehicles worldwide. Every part number is manufactured for the specific application, fitment position on the vehicle, and will provide the relevant diagnostic system feedback as required by the ECU.Newer vehicles will store fault codes in the ECU, some will relate to the affected sensor and its associated systems. A failed sensor might make itself known by causing the engine to run poorly, increase fuel consumption, exhaust emissions, or illuminating a (MIL) malfunction indicator light. The sensor, wiring harness, and connector should also be checked for physical damage. This will most likely also cause their operational life to be shortened.We are an Automotive ISO9001/TS 16949 certified company, with un-paralleled customer service, marketing, and shipping. Our electronic and paper catalogs are designed for today’s fast paced marketplace, along with our eye catching packaging. Since 1946, Walker Products has been the number one choice for the engine management sensors and fuel system components needed for your vehicle.
Brand: Walker
Position: Downstream
Additional Fitment Information:
Vehicle Aspiration Fuel Type Engine VIN Fuel Delivery Type Position Block Engine CID CC
2013 - Kia Optima Turbocharged GAS 6 FI Downstream L 4 Cyl 2.0L 122 1998

Showing 21 - 30 of 49 Products for Oxygen Sensor.